LogoLogo
Search over 1,000 Dental Products

Would you like to tell us about the product?

Endomotor Handpiece
Ratio: 16:1

Brand : Smart Dental Innovations

0.0
0 Reviews

16:1 Endomotor Handpiece Head can be used with rotary NiTi files Designed to aid the endodontic practitioner in efficiently and effectively performing root canal therapy. The operator controls coronal and apical pressure. Miniature push button head can be used with the Waldent Endopro Endomotor.16:1 Endomotor Handpiece Head — miniature push-button head for use with NiTi rotary files (ø2.35mm). Designed for precise coronal and apical control during root canal procedures. Miniature Head For Ni-Ti files (ø2.35) Push Button Chuck Used for NiTi rotary files

Delivery Details
location pin
Product Highlights
  • Materials: Manufactured from medical-grade stainless steel and high-strength alloys for durability and corrosion resistance.
  • Warranty & Support: 1-year limited warranty covering manufacturing defects. Contact supplier for service, parts, or compatibility assistance.
  • Key Features: 16:1 gear ratio head, miniature push-button attachment, designed for use with rotary NiTi files to provide controlled coronal and apical pressure.
  • Compatibility: Compatible with Waldent Endopro endomotor and most standard endomotors supporting 16:1 handpiece heads. Verify coupling type before use.
  • How to Use: Attach head to compatible endomotor, insert NiTi rotary file into chuck, use recommended speed and torque settings, and control apical pressure manually during instrumentation.
  • Sterilization & Maintenance: Autoclave-compatible head: follow manufacturer autoclave cycle recommendations. Wipe external surfaces with approved disinfectant between uses.

The Endomotor Handpiece is a precision-engineered endodontic instrument designed to provide smooth, accurate, and efficient performance during root canal procedures. Built with advanced manufacturing technology and a durable gear reduction mechanism, this handpiece delivers excellent control, stability, and reliability for modern endodontic treatments. Featuring a 16:1 gear ratio, it ensures precise torque transmission and controlled rotary file movement, helping clinicians achieve optimal results while minimizing procedural errors.

  • Precision-Engineered Endodontic Handpiece
  • 16:1 Gear Reduction for Controlled Torque Transmission
  • Smooth and Accurate Rotary File Movement
  • High-Precision Gear Mechanism for Reliable Performance
  • Excellent Stability During Root Canal Procedures
  • Low Vibration and Quiet Operation
  • Ergonomic, Lightweight Design for Comfortable Handling
  • Durable, Corrosion-Resistant Construction
  • Compatible with Standard E-Type Endomotors
  • Supports Efficient and Precise Canal Preparation
  • Minimizes Procedural Errors and File Stress
  • Autoclavable for Safe Sterilization and Repeated Clinical Use
  • Insert the NiTi file securely into the push-button chuck.
  • Ensure the file is properly locked before operation.
  • Connect the handpiece to a compatible E-Type endomotor.
  • Select the appropriate speed, torque, and rotation mode (rotary or reciprocation) on the motor.
  • Gently introduce the file into the prepared root canal using light apical pressure.
  • Use a smooth pecking motion without applying excessive force.
  • Irrigate the canal intermittently to remove debris and minimize heat generation.
  • Withdraw and clean the file periodically during instrumentation.
  • Avoid forcing or bending the file to reduce the risk of file separation.
  • After use, remove the file and sterilize the handpiece according to standard infection control protocols.
  • 1 x Endomotor Handpiece
    6 Month Warranty
    Smart Dental Innovation Benefits
    SecurePayment
    Hassle FreeCancellation*
    7 DaysReplacement*
    100%Genuine
    COD
    Net Banking
    Partial Payment
    Credit / Debit cards

    Would you like to tell us about the product?

    Want to buy even more quantity ?
    FAQs
    question
    How do i operate the endomotor handpiece safely?

    Answer: Attach the head to a compatible endomotor, insert the rotary ni-ti file into the chuck, set recommended speed and torque, and manually control apical pressure during instrumentation.

    question
    What materials is the handpiece made from?

    Answer: The handpiece is manufactured from medical-grade stainless steel and high-strength alloys, ensuring durability and corrosion resistance.

    Endomotor Handpiece
    Ratio: 16:1

    Brand : Smart Dental Innovations

    0.0
    0 Reviews

    16:1 Endomotor Handpiece Head can be used with rotary NiTi files Designed to aid the endodontic practitioner in efficiently and effectively performing root canal therapy. The operator controls coronal and apical pressure. Miniature push button head can be used with the Waldent Endopro Endomotor.16:1 Endomotor Handpiece Head — miniature push-button head for use with NiTi rotary files (ø2.35mm). Designed for precise coronal and apical control during root canal procedures. Miniature Head For Ni-Ti files (ø2.35) Push Button Chuck Used for NiTi rotary files

    Delivery Details
    location pin
    Product Highlights
    • Materials: Manufactured from medical-grade stainless steel and high-strength alloys for durability and corrosion resistance.
    • Warranty & Support: 1-year limited warranty covering manufacturing defects. Contact supplier for service, parts, or compatibility assistance.
    • Key Features: 16:1 gear ratio head, miniature push-button attachment, designed for use with rotary NiTi files to provide controlled coronal and apical pressure.
    • Compatibility: Compatible with Waldent Endopro endomotor and most standard endomotors supporting 16:1 handpiece heads. Verify coupling type before use.
    • How to Use: Attach head to compatible endomotor, insert NiTi rotary file into chuck, use recommended speed and torque settings, and control apical pressure manually during instrumentation.
    • Sterilization & Maintenance: Autoclave-compatible head: follow manufacturer autoclave cycle recommendations. Wipe external surfaces with approved disinfectant between uses.

    The Endomotor Handpiece is a precision-engineered endodontic instrument designed to provide smooth, accurate, and efficient performance during root canal procedures. Built with advanced manufacturing technology and a durable gear reduction mechanism, this handpiece delivers excellent control, stability, and reliability for modern endodontic treatments. Featuring a 16:1 gear ratio, it ensures precise torque transmission and controlled rotary file movement, helping clinicians achieve optimal results while minimizing procedural errors.

  • Precision-Engineered Endodontic Handpiece
  • 16:1 Gear Reduction for Controlled Torque Transmission
  • Smooth and Accurate Rotary File Movement
  • High-Precision Gear Mechanism for Reliable Performance
  • Excellent Stability During Root Canal Procedures
  • Low Vibration and Quiet Operation
  • Ergonomic, Lightweight Design for Comfortable Handling
  • Durable, Corrosion-Resistant Construction
  • Compatible with Standard E-Type Endomotors
  • Supports Efficient and Precise Canal Preparation
  • Minimizes Procedural Errors and File Stress
  • Autoclavable for Safe Sterilization and Repeated Clinical Use
  • Insert the NiTi file securely into the push-button chuck.
  • Ensure the file is properly locked before operation.
  • Connect the handpiece to a compatible E-Type endomotor.
  • Select the appropriate speed, torque, and rotation mode (rotary or reciprocation) on the motor.
  • Gently introduce the file into the prepared root canal using light apical pressure.
  • Use a smooth pecking motion without applying excessive force.
  • Irrigate the canal intermittently to remove debris and minimize heat generation.
  • Withdraw and clean the file periodically during instrumentation.
  • Avoid forcing or bending the file to reduce the risk of file separation.
  • After use, remove the file and sterilize the handpiece according to standard infection control protocols.
  • 1 x Endomotor Handpiece
    6 Month Warranty
    Smart Dental Innovation Benefits
    SecurePayment
    Hassle FreeCancellation*
    7 DaysReplacement*
    100%Genuine
    COD
    Net Banking
    Partial Payment
    Credit / Debit cards

    Would you like to tell us about the product?

    Want to buy even more quantity ?
    FAQs
    question
    How do i operate the endomotor handpiece safely?

    Answer: Attach the head to a compatible endomotor, insert the rotary ni-ti file into the chuck, set recommended speed and torque, and manually control apical pressure during instrumentation.

    question
    What materials is the handpiece made from?

    Answer: The handpiece is manufactured from medical-grade stainless steel and high-strength alloys, ensuring durability and corrosion resistance.

    Related Products
    a
    K-File Reciprocation Handpeice

    variant available from

    ₹9,100

    ₹7,990

    12% OFF

    5.0

    |

    4

    Dentoscope, 10 mm

    variant available from

    ₹21,990

    ₹15,990

    27% OFF

    a
    Twin Force Kit Without Handle

    variant available from

    ₹1,199

    ₹1,100

    8% OFF

    a
    Youni Flexi Extension Clamp (Pack of 2), Molar & Premolar

    variant available from

    ₹1,500

    ₹1,200

    20% OFF

    a
    GP Spike (Gutta Percha Remover), 0.7 x 28mm

    variant available from

    ₹2,200

    ₹1,890

    14% OFF

    a
    Anterior & Posterior Ivory Tooth Separator, Anterior

    variant available from

    ₹1,800

    ₹1,299

    28% OFF

    a
    OptiSmart (LED Portable Light)

    variant available from

    ₹13,000

    ₹9,990

    23% OFF

    Buy onWhatsApp
    Buy Now