The Implant Handpiece from Smart Dental Innovations, as seen in the image, is described as a DentalPlant contra-angle surgical handpiece specifically designed for oral and maxillofacial surgery and implantology
Key Specifications
Key Specifications
Type: Contra-angle surgical handpiece, specifically designed for oral and maxillofacial surgery and implantology.
Gear Ratio: Typically a 20:1 reduction gear ratio, providing high torque and precise control required for implant procedures.
Speed: Operates at low speeds up to approximately 2000 RPM, ideal for controlled drilling in bone.
Max Torque: Offers a maximum torque of around 50-80 Ncm, ensuring sufficient power for implant placement and osteotomy.
Chuck Type: Features a latch-type chuck or a push-button chuck for secure and easy bur changes.
Irrigation System: Equipped with an internal/external irrigation system to prevent bone overheating during drilling and ensure effective cooling.
Material: Constructed from high-quality stainless steel, ensuring durability, hygiene, and resistance to corrosion.
Sealing System: Incorporates a double sealing system to prevent the ingress of fluids like blood and saliva, extending the instrument's lifespan.
Autoclavable: Designed to be autoclavable at up to 135°C, ensuring proper sterilization for patient safety.
Packaging
Packaging
1x
Direction to Use
Direction to Use
Control Unit & Foot Pedal: Turn on the implant motor's control unit and use the foot pedal to control the handpiece speed and activation. Familiarize yourself with the pedal's sensitivity.
Torque Settings: Set the appropriate torque on the implant motor based on bone density and the specific implant system's requirements (e.g., lower torque for softer bone, higher for harder bone).
Drilling Technique: Hold the handpiece with a steady, gentle grip and let the motor and drill do the cutting; avoid applying excessive pressure, which can damage the handpiece or cause thermal injury to the bone.
Irrigation Activation: Ensure the irrigation system is actively providing coolant during drilling to prevent bone overheating.
Monitor Performance: Pay attention to the handpiece's sound and feel. If you notice unusual vibrations, wobbling, or stalling, address the issue promptly, potentially by increasing speed or checking the bur.
3. Post-Procedure Care:
Cleaning: Immediately after use, clean the handpiece thoroughly to remove debris and bioburden. Use a soft brush and suitable cleaning solution as recommended by the manufacturer.
Lubrication: Lubricate the handpiece regularly, ideally after each cleaning and before sterilization, using the recommended lubricant to ensure smooth operation and longevity.
Sterilization: Autoclave the handpiece according to the validated protocols and manufacturer's instructions to ensure complete sterilization.