The retreatment file is a nickel-titanium (NiTi) rotary endodontic instrument used to remove gutta-percha and other root canal filling materials during retreatment. Its progressive taper, cutting flutes, and non-cutting safety tip support filling-material removal from previously treated canals.

Delivery Details
location pin
Product Highlights
  • Material: Nickel–Titanium alloy (NiTi) with heat-treated surface for enhanced flexibility, shape memory and improved cyclic fatigue resistance.
  • Indications: Removal of gutta-percha, carrier-based obturations and retreatment of previously treated root canals; negotiation of curved or blocked canals during retreatment.
  • How to use: Use with a compatible rotary endodontic handpiece at recommended RPM/torque. Begin with coronal flaring, introduce file gently to working length under continuous irrigation and use a brushing motion to remove filling material.
  • Sterilization: Autoclavable. Sterilize according to clinic protocol (e.g., 134°C cycle). Inspect instruments for deformation or corrosion before each use.
  • Pack contents: Set of 6 retreatment files (25mm) in protective blister tray with sleeve and instructions for use.
  • Precautions: Do not apply excessive lateral force. Discard if bent, fractured, or showing signs of metal fatigue. Use by trained dental professionals only.

Removing existing filling material is an important stage when a root canal requires further treatment. The endodontic retreatment file is designed to penetrate filled canals and help remove gutta-percha and residual sealer, allowing access for subsequent canal cleaning and shaping.

Manufactured from heat-treated nickel-titanium alloy, the file is described as offering flexibility and resistance to cyclic fatigue. Its progressive taper and cutting flutes assist in engaging and removing filling material, while the non-cutting safety tip is designed to support canal negotiation. Length markings help clinicians monitor insertion depth during treatment.

The NiTi retreatment file is listed with a 25 mm length and different size and taper variants to accommodate varying canal requirements. It operates in continuous rotation with a compatible endodontic motor using the manufacturer's specified settings.

Suitable file selection depends on the existing root canal filling, canal anatomy, and the selected instrument variant. Appropriate irrigation and controlled handling form part of the retreatment technique. The file should be examined for deformation or fatigue, with cleaning and sterilization carried out according to the manufacturer's guidance.

  • Product Type: Rotary endodontic retreatment file

  • Material: Heat-treated nickel-titanium (NiTi) alloy

  • Primary Application: Removal of gutta-percha and other root canal filling materials

  • File Design: Progressive taper with cutting flutes

  • Tip Design: Non-cutting safety tip

  • Listed Length: 25 mm

  • Operating Motion: Continuous rotation

  • Available Variants: Multiple size and taper options

  • Instrument Properties: Designed for flexibility and cyclic fatigue resistance

  • Equipment Compatibility: Compatible endodontic motor with manufacturer-specified settings

1. Indications for Use

• Intended for removal of existing root canal filling materials such as gutta-percha and sealers.
• Used for canal shaping during endodontic retreatment procedures.


2. Instructions for Use

• Establish straight-line access to the root canal prior to instrumentation.
• Select the appropriate file size according to canal anatomy and clinical requirement.
• Operate the file using a gentle in-and-out (pecking) motion.
• Use recommended motor settings as specified for the file system.
• Irrigate thoroughly between each file to remove debris and softened filling material.
• Continue sequential instrumentation until complete removal of filling material and desired canal shaping is achieved.


3. Recommended Motor Settings

• Speed: 300–500 RPM
• Torque: 2.0–3.5 Ncm (or as recommended by the manufacturer)


4. Precautions

• Do not force the file or apply excessive apical pressure.
• Maintain adequate irrigation and lubrication during use.
• Discard files showing signs of wear, deformation, or unwinding.
• Always use rubber dam isolation during the procedure.

5. Sterilization

• Files may be supplied sterile or non-sterile depending on the manufacturer.
• If non-sterile, autoclave at 134°C for 3–5 minutes before use.
• Single-use is recommended to reduce the risk of file fatigue and separation.


6. Storage

• Store in a clean and dry environment.
• Protect from moisture and corrosive substances.

5 x Retreatment File
No
Smart Dental Innovation Benefits
SecurePayment
Hassle FreeCancellation*
7 DaysReplacement*
100%Genuine
COD
Net Banking
Partial Payment
Credit / Debit cards

Would you like to tell us about the product?

Want to buy even more quantity ?
FAQs
question
What is a retreatment file made of?

Answer: A retreatment file is made from nickel–titanium alloy (niti) with a heat-treated surface to enhance flexibility, shape memory, and cyclic fatigue resistance.

question
How does a retreatment file work?

Answer: It uses super-elastic and shape-memory properties of niti to flexibly negotiate curved or narrow root canals while applying cutting forces to remove existing filling materials like gutta-percha and sealers.

Retreatment File
Length: 25mm

Brand : Smart Dental Innovations

0.0
0 Reviews

The retreatment file is a nickel-titanium (NiTi) rotary endodontic instrument used to remove gutta-percha and other root canal filling materials during retreatment. Its progressive taper, cutting flutes, and non-cutting safety tip support filling-material removal from previously treated canals.

Delivery Details
location pin
Product Highlights
  • Material: Nickel–Titanium alloy (NiTi) with heat-treated surface for enhanced flexibility, shape memory and improved cyclic fatigue resistance.
  • Indications: Removal of gutta-percha, carrier-based obturations and retreatment of previously treated root canals; negotiation of curved or blocked canals during retreatment.
  • How to use: Use with a compatible rotary endodontic handpiece at recommended RPM/torque. Begin with coronal flaring, introduce file gently to working length under continuous irrigation and use a brushing motion to remove filling material.
  • Sterilization: Autoclavable. Sterilize according to clinic protocol (e.g., 134°C cycle). Inspect instruments for deformation or corrosion before each use.
  • Pack contents: Set of 6 retreatment files (25mm) in protective blister tray with sleeve and instructions for use.
  • Precautions: Do not apply excessive lateral force. Discard if bent, fractured, or showing signs of metal fatigue. Use by trained dental professionals only.

Removing existing filling material is an important stage when a root canal requires further treatment. The endodontic retreatment file is designed to penetrate filled canals and help remove gutta-percha and residual sealer, allowing access for subsequent canal cleaning and shaping.

Manufactured from heat-treated nickel-titanium alloy, the file is described as offering flexibility and resistance to cyclic fatigue. Its progressive taper and cutting flutes assist in engaging and removing filling material, while the non-cutting safety tip is designed to support canal negotiation. Length markings help clinicians monitor insertion depth during treatment.

The NiTi retreatment file is listed with a 25 mm length and different size and taper variants to accommodate varying canal requirements. It operates in continuous rotation with a compatible endodontic motor using the manufacturer's specified settings.

Suitable file selection depends on the existing root canal filling, canal anatomy, and the selected instrument variant. Appropriate irrigation and controlled handling form part of the retreatment technique. The file should be examined for deformation or fatigue, with cleaning and sterilization carried out according to the manufacturer's guidance.

  • Product Type: Rotary endodontic retreatment file

  • Material: Heat-treated nickel-titanium (NiTi) alloy

  • Primary Application: Removal of gutta-percha and other root canal filling materials

  • File Design: Progressive taper with cutting flutes

  • Tip Design: Non-cutting safety tip

  • Listed Length: 25 mm

  • Operating Motion: Continuous rotation

  • Available Variants: Multiple size and taper options

  • Instrument Properties: Designed for flexibility and cyclic fatigue resistance

  • Equipment Compatibility: Compatible endodontic motor with manufacturer-specified settings

1. Indications for Use

• Intended for removal of existing root canal filling materials such as gutta-percha and sealers.
• Used for canal shaping during endodontic retreatment procedures.


2. Instructions for Use

• Establish straight-line access to the root canal prior to instrumentation.
• Select the appropriate file size according to canal anatomy and clinical requirement.
• Operate the file using a gentle in-and-out (pecking) motion.
• Use recommended motor settings as specified for the file system.
• Irrigate thoroughly between each file to remove debris and softened filling material.
• Continue sequential instrumentation until complete removal of filling material and desired canal shaping is achieved.


3. Recommended Motor Settings

• Speed: 300–500 RPM
• Torque: 2.0–3.5 Ncm (or as recommended by the manufacturer)


4. Precautions

• Do not force the file or apply excessive apical pressure.
• Maintain adequate irrigation and lubrication during use.
• Discard files showing signs of wear, deformation, or unwinding.
• Always use rubber dam isolation during the procedure.

5. Sterilization

• Files may be supplied sterile or non-sterile depending on the manufacturer.
• If non-sterile, autoclave at 134°C for 3–5 minutes before use.
• Single-use is recommended to reduce the risk of file fatigue and separation.


6. Storage

• Store in a clean and dry environment.
• Protect from moisture and corrosive substances.

5 x Retreatment File
No
Smart Dental Innovation Benefits
SecurePayment
Hassle FreeCancellation*
7 DaysReplacement*
100%Genuine
COD
Net Banking
Partial Payment
Credit / Debit cards

Would you like to tell us about the product?

Want to buy even more quantity ?
FAQs
question
What is a retreatment file made of?

Answer: A retreatment file is made from nickel–titanium alloy (niti) with a heat-treated surface to enhance flexibility, shape memory, and cyclic fatigue resistance.

question
How does a retreatment file work?

Answer: It uses super-elastic and shape-memory properties of niti to flexibly negotiate curved or narrow root canals while applying cutting forces to remove existing filling materials like gutta-percha and sealers.

Related Products
a
Electric Brushless Motor With Tank + 1:5 Fiber Optic Push Button Handpiece + Surgical Straight Handpiece + Contra Angle Handpiece

variant available from

₹50,000

₹40,000

20% OFF

a
Endomotor Handpiece, 16:1

variant available from

₹3,990

₹2,990

25% OFF

a
Youni X File (Pack Of 50)

variant available from

₹32,000

₹29,950

6% OFF

a
Twin Force Kit Without Handle

variant available from

₹2,000

₹1,450

28% OFF

a
3x Magnifying Mirror

variant available from

₹1,000

₹700

30% OFF

a
GP Spike (Gutta Percha Remover), 0.7 x 28mm

variant available from

₹2,200

₹1,890

14% OFF

5.0

|

1

Aero Blast Pro With Powder

variant available from

₹25,000

₹19,999

20% OFF

Buy onWhatsApp
Buy Now